The main function of the steel structure is to support the EWS-104 cladding on the four sides of the building.
The overall shape can be represented as the union of three triangles; the side triangles have an almost vertical slope, while the middle triangle has a slope of about 18° from the vertical.
All architectural elements of the facade are built sections: the transoms have a triangular cross-section, while the mullion between the facades has a diamond cross-section.
The facade stands on the ground, while the intermediate connections are subject only to wind load.